Gas Endeavour®
|
AMPTS® II
|
AMPTS® II Light
|
BioReactor Simulator
|
Examples of application areas
|
in-vitro digestability anaerobic biodegradability, bioethanol production, yeast fermentation and many more
|
Anaerobic fermentation tests in batch mode (e.g. BMP, SMA, RGP, substrate inhibition tests) and biohydrogen potential (dark fermentation).
|
Anaerobic digestion experiments in batch mode (e.g. BMP, SMA, RGP, substrate inhibition tests) and biohydrogen potential (dark fermentation).
|
Continuous biogas production experiments (anaerobic fermentation test in continuous mode)
|
Software
|
Embedded software accessed with web browser. No installation needed
|
Embedded software accessed with web browser. No installation needed
|
Embedded software accessed with web browser. No installation needed
|
Online software
|
Internet access needed
|
No
|
No
|
No
|
Yes
|
Data storage
|
Locally
Up to 900 l (200 l with 2 ml flow cells) of gas can be stored at once
|
Locally
Up to 900 l of gas can be stored at once
|
Locally
Up to 900 l of gas can be stored at once
|
Cloud based server
Unlimited storage capacity
|
Experiment guidelines
|
No
|
Yes
|
Yes
|
Yes
|
Measurement resolution
|
2 or 9 ml
|
9 ml
|
9 ml
|
9 ml
|
Test lines
|
15
|
15
|
6
|
6
|
Incubation bottles
|
250, 500 (standard) or 1000 ml
|
500 ml
|
2000 ml
|
2000 ml with ports for feeding and discharging or lab-scale bioreactor in various configurations (optional)
|
Mixing
|
Mechanical agitation (standard) or shaking
|
Mechanical agitation
|
Mechanical agitation
|
Mechanical agitation
|
Gas removal unit
|
Yes (ex-situ)
|
Yes (ex-situ)
|
Yes (ex-situ)
|
No
|
Operation mode
|
Batch
|
Batch
|
Batch
|
Continuous
|
Maintenance
|
Easy maintenance. Most parts can be replaced without the need to ship instrument to the manufacture or a regional service center
|
Some repairs require returning of instrument to the manufacture or a regional service center
|
Some repairs require shipping of instrument to the manufacture or a regional service center
|
Some repairs require shipping of instrument to the manufacture or a regional service center
|
Gas types that can be measured
|
Most nonaggressive gases, e.g. biogas, methane, carbon dioxide, nitrogen gas, hydrogen gas, etc…
|
Methane, hydrogen gas and nitrogen gas
|
Methane, hydrogen gas and nitrogen gas
|
Biogas, methane, hydrogen gas and nitrogen gas
|
Gas composition determination possible
|
Yes
|
No*
|
No*
|
No
|
Gas collection possible
|
Yes
|
No
|
No
|
No
|
* Possible in combination with a Gas Endeavor detection unit
|