Real-time process monitoring made easy

BPC DAQ enables real-time acquisition of analogue sensor data alongside gas production measurements, with all signals collected and stored in the BPC Go software.

Laboratory instrument BPC DAQ used for gas data acquisition

Process monitoring for BPC Go systems

Article No. 303-0001-00

The BPC DAQ is the newest accessory for your BPC Go system. The unit connects directly to BPC Go and can be equipped with up to four analogue sensors, including: 

In the BPC Go software, signals from all connected sensors are collected and stored. The BPC DAQ extends the use of BPC Go by enabling monitoring of additional real-time parameters alongside gas production.

 

Need more information?

Want a quote or a quick walk through from our technical experts? Choose what suits you below.

SENSORS

Seamless compatibility

With plug-and-play functionality, the BPC DAQ allows straightforward integration of analogue sensors with the BPC Go system. The unit is equipped with four analogue ports with automatic passive and active signal detection, allowing connection to a wide range of commercially available sensors without manual configuration.

Laboratory instrument BPC DAQ used for gas data acquisition
In-line pH or ORP monitoring set
Submersion and In-line pH or ORP electrode
In-line temperature probe
pH / ORP transmitter

FEATURES

Engineered for reliable data acquisition

Integration

Direct connection to BPC Go for power and data handling.

Compatibility

Supports analogue sensors with automatic signal detection.

Configuration

Sensor units and sampling configured in BPC Go software.

Stability

Compact design with anti-slip base for lab use.

Laboratory instrument BPC DAQ used for gas data acquisition

Technical specifications

Laboratory instrument BPC DAQ used for gas data acquisition

BPC DAQ

Article No. 303-0001-00

  • Compatible Main Unit: BPC Go
  • Analogue Inputs: 4 x DC jack 2.5/5.5 mm (4-20 mA); automatic passive/active detection
  • Digital Input: 1 x RJ12 connector
  • Sampling Frequency: From 1 minute and upwards (configured using BPC Go)
  • Operating Mode: Passive data acquisition (requires BPC Go connection)
  • Power Supply: Fixed USB‑A cable from BPC Go (5 V DC)
  • Material: Plastic enclosure with embedded electronics and metal screws.
  • Anti-Slip Base: EPDM rubber pad
  • Dimensions: Ø 74 mm × 32 mm
  • Weight: 90 g
  • Operating Temperature: -20 to 60 °C
  • Operating Humidity: 10–90% RH, non‑condensing
  • Operating Environment: Indoor use only

Article No. 11-0005-02

In-line ORP monitoring set

Article No. 11-0002-01

Submersion and In-line pH electrode

Article No. 11-0005-01

Submersion and In-line ORP electrode

  • Flat-surface ORP electrode (± 2000 mV) for measuring slurries, sludge and viscous samples, as well as those containing suspended solids; high H2S resistance 
  • ORP transmitter with display and 4-20 mA signal output
  • Shielded electrode signal cable 
  • Shielded signal cable for data logger (optional and only applies to BPC’s data loggers)
  • Electrode mounting gland for in-line applications (optional and only applies to BPC’s stainless-steel bioreactors)
  • Power supply: Powered through data logger or 12-24 VDC, max 600 Ohm load
  • Usage: laboratory applications
  • Measuring range: 0-14 pH
  • Comb pH electrode, Din 13.5 mm cap
  • Flat measurement tip for surface measurements
  • Double junction electrode design prevents reference contamination
  • High H2S resistance and suitable for measuring slurries, sludge and viscous samples, as well as those containing suspended solids
  • Durable Ultem body offers enhanced chemical compatibility and booted BNC protects meter connection.
  • Dimension: 150 mm (length), 12 mm (diameter)
  • Usage: laboratory applications
  • Measuring range: ± 2000 mV for ORP models
  • Comb ORP electrode, Din 13.5 mm cap
  • Temperature range: 0 to 100 oC
  • Flat measurement tip for surface measurements
  • Double junction electrode design prevents reference contamination
  • High H2S resistance and suitable for measuring slurries, sludge and viscous samples, as well as those containing suspended solids
  • Durable Ultem body offers enhanced chemical compatibility and booted BNC protects meter connection.
  • Dimension: 150 mm (length), 12 mm (diameter)
  • Usage: laboratory applications

Article No. 11-0006-01

In-line temperature probe

Article No. 11-0007-01

ph / ORP transmitter

  • Pt 1000 (DIN EN 60751, class A)
  • Measuring range: -50 to 150 oC
  • Resolution: 0.04 oC
  • Precision analogue output: ± 0.3 + (± 0.1 % MS)
  • Analogue current output: 4-20 mA
  • Operating voltage: 18-32 VDC
  • Materials: stainless-steel (316L); O-ring: FKM
  • Weight: 128.5 g
  • Probe diameter: 6 mm
  • Installation length EL: 100 mm
  • Usage: indoor
  • Measuring range (pH): 0-14 pH, 0.01 pH resolution, ± 0.01 accuracy
  • Measuring range (ORP/mV): ± 2000 mV, 1 mV resolution, ±2 mV accuracy
  • Temperature range: -20 to 110 oC, 0.1 oC resolution
  • Current output range: 4-20 mA, 0.01 mA resolution, ±0.005 mA accuracy, 500 V input/output isolation
  • Temperature input: 2-wire PT1000 RTD with automatic compensation
  • Power requirement: Powered through data logger or 12-24 VDC, max 600 Ohm load
  • Maximum sensor to transmitter distance: 9 meters
  • Mounting options: wall, panel, din rail, and pipe
  • Dimension: 99 mm (H) x 99 mm (W) x 75 mm (D)
  • Weight: approximately 0.45 kg
  • Usage: indoor

Download the BPC Go & DAQ folder. 

Laboratory instrument BPC DAQ used for gas data acquisition

Interested in BPC DAQ?

Get in touch and we’ll help you choose a suitable sensor configuration for BPC DAQ.

Explore our extensive selection of analytical instruments

Achieve better outcomes in both research and industry with our smart, resource-efficient instruments. Designed to help you analyse more samples with greater precision while saving time and effort, our solutions are built to support your success.

Request a quote

Use the form below to request pricing. Share what you’re interested in and any relevant details, and we’ll come back with a quotation and lead time as soon as possible.